{"product_id":"fortinet-fortiswitch-448d","title":"Fortinet FortiSwitch 448D","description":"\u003ch2 data-start=\"133\" data-end=\"175\"\u003e\u003cstrong data-start=\"136\" data-end=\"175\"\u003eFortinet FortiSwitch 448D (FS-448D)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"177\" data-end=\"580\"\u003eThe \u003cstrong data-start=\"181\" data-end=\"201\"\u003eFortiSwitch 448D\u003c\/strong\u003e is a high-density, secure access Layer 2\/3 Ethernet switch designed for enterprise branch offices, distributed networks, and converged deployments where performance, PoE support (in POE variants), and centralized security management are essential. Tight integration with \u003cstrong data-start=\"473\" data-end=\"486\"\u003eFortiGate\u003c\/strong\u003e via \u003cstrong data-start=\"491\" data-end=\"504\"\u003eFortiLink\u003c\/strong\u003e enables unified management of switching and security from a single console.\u003c\/p\u003e\n\u003ch3 data-start=\"582\" data-end=\"598\"\u003e\u003cstrong data-start=\"586\" data-end=\"598\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"599\" data-end=\"920\"\u003e\n\u003cli data-start=\"599\" data-end=\"647\"\u003e\n\u003cp data-start=\"601\" data-end=\"647\"\u003ePart of the FortiSwitch Secure Access Series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"648\" data-end=\"716\"\u003e\n\u003cp data-start=\"650\" data-end=\"716\"\u003eDesigned for scalable access deployments with optional PoE power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"717\" data-end=\"776\"\u003e\n\u003cp data-start=\"719\" data-end=\"776\"\u003eManaged standalone or centrally via FortiGate FortiLink\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"777\" data-end=\"849\"\u003e\n\u003cp data-start=\"779\" data-end=\"849\"\u003eSuitable for wiring closets, MDF\/IDF closets, and edge access layers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"850\" data-end=\"920\"\u003e\n\u003cp data-start=\"852\" data-end=\"920\"\u003eUp to 48 ports plus high-speed uplinks in a compact 1 RU form factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"922\" data-end=\"925\"\u003e\n\u003ch2 data-start=\"927\" data-end=\"959\"\u003e\u003cstrong data-start=\"930\" data-end=\"957\"\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"960\" data-end=\"1369\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"960\" data-end=\"990\"\u003e\n\u003ctr data-start=\"960\" data-end=\"990\"\u003e\n\u003cth data-start=\"960\" data-end=\"970\" data-col-size=\"sm\" class=\"\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"970\" data-end=\"990\" data-col-size=\"md\" class=\"\"\u003eFortiSwitch 448D\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1022\" data-end=\"1369\"\u003e\n\u003ctr data-start=\"1022\" data-end=\"1118\"\u003e\n\u003ctd data-start=\"1022\" data-end=\"1053\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1024\" data-end=\"1052\"\u003eTotal Network Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1053\" data-end=\"1118\" data-col-size=\"md\"\u003e48 x GE RJ45 + 4 x 10 GE SFP+ (SFP+ compatible with 1 GE SFP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1119\" data-end=\"1170\"\u003e\n\u003ctd data-start=\"1119\" data-end=\"1151\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1121\" data-end=\"1150\"\u003eDedicated Management Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1151\" data-end=\"1170\" data-col-size=\"md\"\u003e1 x 10\/100 RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1171\" data-end=\"1208\"\u003e\n\u003ctd data-start=\"1171\" data-end=\"1203\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1173\" data-end=\"1202\"\u003eRJ-45 Serial Console Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1203\" data-end=\"1208\" data-col-size=\"md\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1209\" data-end=\"1246\"\u003e\n\u003ctd data-start=\"1209\" data-end=\"1227\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1211\" data-end=\"1226\"\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1227\" data-end=\"1246\" data-col-size=\"md\"\u003e1 RU Rack Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1247\" data-end=\"1290\"\u003e\n\u003ctd data-start=\"1247\" data-end=\"1285\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1249\" data-end=\"1284\"\u003ePower over Ethernet (PoE) Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1285\" data-end=\"1290\" data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1291\" data-end=\"1321\"\u003e\n\u003ctd data-start=\"1291\" data-end=\"1314\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1293\" data-end=\"1313\"\u003ePoE Power Budget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1314\" data-end=\"1321\" data-col-size=\"md\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1322\" data-end=\"1369\"\u003e\n\u003ctd data-start=\"1322\" data-end=\"1355\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1324\" data-end=\"1354\"\u003eMean Time Between Failures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1355\" data-end=\"1369\" data-col-size=\"md\"\u003e\u0026gt; 10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1371\" data-end=\"1374\"\u003e\n\u003ch2 data-start=\"1376\" data-end=\"1406\"\u003e\u003cstrong data-start=\"1379\" data-end=\"1404\"\u003eSystem Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1407\" data-end=\"1798\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1407\" data-end=\"1424\"\u003e\n\u003ctr data-start=\"1407\" data-end=\"1424\"\u003e\n\u003cth data-start=\"1407\" data-end=\"1421\" data-col-size=\"sm\" class=\"\"\u003ePerformance\u003c\/th\u003e\n\u003cth data-start=\"1421\" data-end=\"1424\" data-col-size=\"sm\" class=\"\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1443\" data-end=\"1798\"\u003e\n\u003ctr data-start=\"1443\" data-end=\"1489\"\u003e\n\u003ctd data-start=\"1443\" data-end=\"1477\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1445\" data-end=\"1476\"\u003eSwitching Capacity (Duplex)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1477\" data-end=\"1489\" data-col-size=\"sm\"\u003e176 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1490\" data-end=\"1536\"\u003e\n\u003ctd data-start=\"1490\" data-end=\"1524\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1492\" data-end=\"1523\"\u003ePackets Per Second (Duplex)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1524\" data-end=\"1536\" data-col-size=\"sm\"\u003e262 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1537\" data-end=\"1571\"\u003e\n\u003ctd data-start=\"1537\" data-end=\"1563\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1539\" data-end=\"1562\"\u003eMAC Address Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1563\" data-end=\"1571\"\u003e16 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1572\" data-end=\"1604\"\u003e\n\u003ctd data-start=\"1572\" data-end=\"1594\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1574\" data-end=\"1593\"\u003eNetwork Latency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1594\" data-end=\"1604\" data-col-size=\"sm\"\u003e\u0026lt; 1 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1605\" data-end=\"1634\"\u003e\n\u003ctd data-start=\"1605\" data-end=\"1627\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1607\" data-end=\"1626\"\u003eVLANs Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1627\" data-end=\"1634\" data-col-size=\"sm\"\u003e4 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1635\" data-end=\"1674\"\u003e\n\u003ctd data-start=\"1635\" data-end=\"1669\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1637\" data-end=\"1668\"\u003eLink Aggregation Group Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1669\" data-end=\"1674\" data-col-size=\"sm\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1675\" data-end=\"1723\"\u003e\n\u003ctd data-start=\"1675\" data-end=\"1698\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1677\" data-end=\"1697\"\u003eTotal LAG Groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1698\" data-end=\"1723\" data-col-size=\"sm\"\u003eUp to number of ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1724\" data-end=\"1755\"\u003e\n\u003ctd data-start=\"1724\" data-end=\"1745\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1726\" data-end=\"1744\"\u003ePacket Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1745\" data-end=\"1755\" data-col-size=\"sm\"\u003e1.5 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1756\" data-end=\"1775\"\u003e\n\u003ctd data-start=\"1756\" data-end=\"1767\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1758\" data-end=\"1766\"\u003eDRAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1767\" data-end=\"1775\" data-col-size=\"sm\"\u003e1 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1776\" data-end=\"1798\"\u003e\n\u003ctd data-start=\"1776\" data-end=\"1788\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1778\" data-end=\"1787\"\u003eFlash\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1788\" data-end=\"1798\"\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1800\" data-end=\"1803\"\u003e\n\u003ch2 data-start=\"1805\" data-end=\"1838\"\u003e\u003cstrong data-start=\"1808\" data-end=\"1836\"\u003eDimensions \u0026amp; Environment\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1839\" data-end=\"2440\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1839\" data-end=\"1866\"\u003e\n\u003ctr data-start=\"1839\" data-end=\"1866\"\u003e\n\u003cth data-start=\"1839\" data-end=\"1849\" data-col-size=\"sm\" class=\"\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1849\" data-end=\"1866\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1895\" data-end=\"2440\"\u003e\n\u003ctr data-start=\"1895\" data-end=\"1969\"\u003e\n\u003ctd data-start=\"1895\" data-end=\"1924\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1897\" data-end=\"1923\"\u003eHeight x Depth x Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1924\" data-end=\"1969\" data-col-size=\"md\"\u003e1.75 x 12.2 x 17.3 in (44 x 310 x 440 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1970\" data-end=\"2005\"\u003e\n\u003ctd data-start=\"1970\" data-end=\"1983\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1972\" data-end=\"1982\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1983\" data-end=\"2005\" data-col-size=\"md\"\u003e9.15 lbs (4.15 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2006\" data-end=\"2053\"\u003e\n\u003ctd data-start=\"2006\" data-end=\"2027\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2008\" data-end=\"2026\"\u003ePower Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2027\" data-end=\"2053\" data-col-size=\"md\"\u003e100Å“240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2054\" data-end=\"2088\"\u003e\n\u003ctd data-start=\"2054\" data-end=\"2073\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2056\" data-end=\"2072\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2073\" data-end=\"2088\"\u003eAC built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2089\" data-end=\"2134\"\u003e\n\u003ctd data-start=\"2089\" data-end=\"2111\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2091\" data-end=\"2110\"\u003eRedundant Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2111\" data-end=\"2134\" data-col-size=\"md\"\u003eDual power supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2135\" data-end=\"2194\"\u003e\n\u003ctd data-start=\"2135\" data-end=\"2159\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2137\" data-end=\"2158\"\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2159\" data-end=\"2194\" data-col-size=\"md\"\u003e38 W (average) \/ 38 W (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2195\" data-end=\"2231\"\u003e\n\u003ctd data-start=\"2195\" data-end=\"2218\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2197\" data-end=\"2217\"\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2218\" data-end=\"2231\" data-col-size=\"md\"\u003e147 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2232\" data-end=\"2283\"\u003e\n\u003ctd data-start=\"2232\" data-end=\"2260\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2234\" data-end=\"2259\"\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2260\" data-end=\"2283\" data-col-size=\"md\"\u003e32Å“122 °F (0Å“50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2284\" data-end=\"2335\"\u003e\n\u003ctd data-start=\"2284\" data-end=\"2310\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2286\" data-end=\"2309\"\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2310\" data-end=\"2335\" data-col-size=\"md\"\u003e-4Å“158 °F (-20Å“70 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2336\" data-end=\"2376\"\u003e\n\u003ctd data-start=\"2336\" data-end=\"2351\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2338\" data-end=\"2350\"\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2351\" data-end=\"2376\" data-col-size=\"md\"\u003e10Å“90% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2377\" data-end=\"2440\"\u003e\n\u003ctd data-start=\"2377\" data-end=\"2397\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2379\" data-end=\"2396\"\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2397\" data-end=\"2440\" data-col-size=\"md\"\u003eFCC, CE, RCM, VCCI, BSMI, UL, CB, RoHS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2442\" data-end=\"2445\"\u003e\n\u003ch2 data-start=\"2447\" data-end=\"2500\"\u003e\u003cstrong data-start=\"2450\" data-end=\"2498\"\u003eManagement \u0026amp; Features (Secure Access Series)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2501\" data-end=\"2566\"\u003eAs part of the FortiSwitch Secure Access Series, 448D supports:\u003c\/p\u003e\n\u003cul data-start=\"2567\" data-end=\"3017\"\u003e\n\u003cli data-start=\"2567\" data-end=\"2671\"\u003e\n\u003cp data-start=\"2569\" data-end=\"2671\"\u003e\u003cstrong data-start=\"2569\" data-end=\"2607\"\u003eFortiLink management via FortiGate\u003c\/strong\u003e (centralised VLANs, PoE control, stacking, firmware upgrades)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2672\" data-end=\"2730\"\u003e\n\u003cp data-start=\"2674\" data-end=\"2730\"\u003e\u003cstrong data-start=\"2674\" data-end=\"2699\"\u003e802.1X authentication\u003c\/strong\u003e (port-based, MAC-based, MAB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2731\" data-end=\"2777\"\u003e\n\u003cp data-start=\"2733\" data-end=\"2777\"\u003e\u003cstrong data-start=\"2733\" data-end=\"2775\"\u003eDHCP Snooping, IGMP Snooping, LLDP\/MED\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2778\" data-end=\"2835\"\u003e\n\u003cp data-start=\"2780\" data-end=\"2835\"\u003e\u003cstrong data-start=\"2780\" data-end=\"2833\"\u003eSpanning Tree (STP\/RSTP\/MSTP), LACP, Jumbo Frames\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2836\" data-end=\"2930\"\u003e\n\u003cp data-start=\"2838\" data-end=\"2930\"\u003e\u003cstrong data-start=\"2838\" data-end=\"2875\"\u003eCentralised security \u0026amp; visibility\u003c\/strong\u003e with identification and access control via FortiGate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2931\" data-end=\"3017\"\u003e\n\u003cp data-start=\"2933\" data-end=\"3017\"\u003e\u003cstrong data-start=\"2933\" data-end=\"2956\"\u003eManagement options:\u003c\/strong\u003e Web GUI, CLI, SNMP v1\/v2c\/v3, REST API, Syslog, SSH, HTTPS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fortinet","offers":[{"title":"SW License for FS-400 Series Switches to activate Advanced Features \/ Hardware Only","offer_id":51418503610666,"sku":"FS-SW-LIC-400","price":439.59,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0979\/0754\/0266\/files\/FortinetFortiSwitch448D.png?v=1776574003","url":"https:\/\/fortisecure.store\/products\/fortinet-fortiswitch-448d","provider":"Forti SecureStore","version":"1.0","type":"link"}